3. We had an NBN tech come out 2 weeks ago and he said he tuned the signal by replacing the silver box in the outside Nbn box. CFC/HFC Free Yes. But yeah its just been so bad this weekend. First nbn tech appointment to look into issue was booked for this morning but no show. posted 2019-May-20, 2:03 am AEST CEDAR: HYDRA FLEX COVERALL • EN343 3:1 • Waterproof coverall • Taped, stitched welded seams • Zip front fastening • Studded double storm flap • Fixed hood with draw cord • Stud adjusters at cuffs bottoms Tonight alone my connection has dropped out every 1 or 2 hours for about 5-10 minutes each time. If you find out they do, have ABB pester NBN with that info.That's not a flap – you're describing something more like a stall. Because of the differences in the European "CMTS Troubleshooting and Network Management Features Configuration Guide"In 2017, Multimedia over Coax Alliance introduced MoCA Access specification, based on the MoCA 2.5 standard, suitable for addressing broadband network access in-building using coaxial cabling. A+ energy rating. Usually, if there is a problem with the RF plant, then L2 connectivity is not established. (I was talking to the guy doing that) After that he figured it must be related to the power. All rights reserved.

It keeps a history of the tests you ran. If your service flaps then there is something wrong, don't give up reporting a fault. posted 2019-May-15, 7:25 am AEST Noise Level dB(A) 42. Mud Flaps Small 20" Material: Safepass Color: Black Size: 19″x20″ HFC. Packets received that were generated using a protocol unknown to the Cisco uBR7246. Ive just done a NTD test through the aussiebroadband service tests and my total flaps have been reset to 0 from 367 whats the deal with that?.

:( When all of these impairments are considered, the cumulative effect on the Broadcom SNR estimate means that it is a value lower than the CNR that would be measured with a spectrum analyzer. Average percentage of slots available for modems to request bandwidth through contention mechanisms.

posted 2019-Aug-18, 10:04 pm AEST The value in the P-Adj column may be low. Expect many flap list entries and low Service ID (SID) connectivity numbers. NTD has been flapping like crazy (at least 10 times a day, usually more) since around mid last week. It finishes with an explanation of the Carrier-to-interference ratio for total power (discrete and broadband ingress signals). Deleted, reposted in ABB HFC dropouts threadI had a similar(ish) thing happened to me. posted 2019-Sep-28, 5:29 pm AEST

First, check the upstream interface, ensuring that the configuration is correct. Or alternatively have no interest in keep quality notes after a visit (time pressures perhaps), or something like that :-( If the modem finally comes back online, an insertion is counted, because the cable modem inserted itself back into an active state. The RF plant can be thought of as a MAC Layer 2 (L2) equivalent. Climate Class ST/N/SN. Freezer Specification. The MAC scheduler queue showing the number of ranging polls.The SNR estimation process uses only packets that are free from uncorrectable forward error corrections (FEC) errors and is averaged over 10,000 received symbols. NBN will just keep closing tickets for every reason under the sun. The internet would drop religiously in the morning and evening. When the issues start up again, be sure to have ABB tell NBN it's a continuation / reemergence of an existing / unresolved issue.

posted 2019-Oct-4, 10:38 am AEST posted 2019-Oct-4, 10:38 am AEST I'm around 3 weeks away from having to cancel my ABB to afford to pay for more mobile broadband so I can continue to work. This measurement at the cable modem can pose the following problems:The Data-over-Cable Service Interface Specifications (DOCSIS) protocolThe optimal period to collect the 10,000 symbols is 10-20 ms of 100% utilization upstream for a 3.2 or 1.6 MHz channel width. Talked to ABB and it seems that NBN has acknowledged that the issue is with the network not in my home. posted 2019-May-16, 8:11 am AEST posted 2019-May-8, 5:41 pm AEST I personally think that's pathetic so I suggest you raise a ticket anyway. posted 2019-May-27, 10:31 am AEST Both yesterday and today, I noticed the flap/stall – at least two times and both times for at least 10 minutes. Annex A or B framing format is automatically set when configuring Cisco cable modem cards. From -16 to +26 dBmV, depending on symbol rate.Different Media Cards (MCs) have different output power on the downstream port. posted 2019-May-27, 11:20 am AEST Error packets received through the upstream interface that were corrected.

Current (A) 1.16A.

Do you know if this is possible? It then illustrates the major configuration parameters and commands to issue to verify the downstream and upstream channels. Power Cut Safe Time (hrs) 16. posted 2019-May-7, 10:22 am AEST posted 2019-May-14, 1:39 pm AEST